How Many kWh Does a Range Hood / Exhaust Fan Use?
Range Hood / Exhaust Fan energy cost calculator - see your exact daily, monthly, and yearly electricity cost.
US national average. Edit for your local rate.
Range Hood Type Preset
Fan watts. Lighting is separate: halogen 2x50W vs LED ~10W.
Daily Energy Use
0.20
kWh / day
Monthly Cost
$1.09
Yearly Cost
$13.26
Range Hood / Exhaust Fan - Cost Breakdown
| Period | kWh Used | Cost ($) |
|---|---|---|
| Per Hour | 0.2000 | $0.0363 |
| Per Day | 0.20 | $0.04 |
| Per Month (30 days) | 6.00 | $1.09 |
| Per Year (365 days) | 73.00 | $13.26 |
Running a range hood for an hour uses about the same energy as running a ceiling fan for 2.5 hours.
3 Ways to Cut Your Range Hood / Exhaust Fan Energy Bill
- 🌱
Use the lowest effective speed setting — low speed uses about 40% less energy than high while still capturing most cooking vapors.
- 💡
Clean or replace the grease filter monthly to maintain proper airflow and prevent the motor from working harder.
- ⚡
Turn the hood on a few minutes before cooking to establish airflow, which is more efficient than trying to clear a smoky kitchen after.
The fan motor draws a brief startup surge of about 400–500W before settling to its running wattage.
How Much Electricity Does a Range Hood Really Use?
Last Updated: October 2026 | Reviewed by James Vance, Licensed Master Electrician
Here is the surprise most kitchen shoppers miss: the fan in a typical range hood draws only 65 to 300 watts, about the same as a couple of old incandescent bulbs. Run it for the one hour a day most families actually cook, and it uses about 24 to 110 kWh a year. That is roughly $4 to $20 a year at current rates. The fan itself is one of the cheapest things to run in your kitchen.
ENERGY STAR holds range hoods to a minimum of 2.8 CFM per watt, and good certified models do far better, with some hitting 16 CFM per watt or more. A 150 CFM hood on an efficient model can draw barely 10 to 20 watts. The flip side is the 900 CFM pro-style monsters on Amazon that draw 500 to 700 watts. You pay for every CFM twice: once in the fan motor, and once in the heated or cooled air it throws out the window.
I have wired dozens of kitchen remodels, and the thing I tell every homeowner is this: the electricity for the fan is not the expensive part. The expensive part is the makeup air. Exhaust 600 cubic feet of warm air every minute, and your furnace has to heat 600 cubic feet of cold outdoor air to replace it. That cost dwarfs the fan's own draw, and not one competitor page I have seen bothers to say it.
Range Hood Types: Real Energy Numbers
Fan wattage is nameplate; annual kWh is estimated from 1 hour/day runtime. Lighting wattage depends on bulb type (halogen 2x50W vs LED ~10W) and is separate.
| Type | Fan Wattage | Annual Use | Notes |
|---|---|---|---|
| Under-cabinet / slide-out, ducted | 65-150W fan | ~24-55 kWh/year (estimate) | Single small motor, lowest draw in the class. The classic apartment hood. About $4-10 a year to run. |
| Wall-mount chimney / insert, ducted | 150-300W fan | ~55-110 kWh/year (estimate) | The most common type. High speed roughly doubles wattage over low. About $10-20 a year at typical use. |
| Island / pro-style high-CFM, ducted | 300-700W fan | ~110-256 kWh/year (estimate) | Big blowers moving 600+ CFM. Only buy if your burner BTU math needs it. Over 400 CFM triggers makeup-air code rules in many areas. |
| Recirculating (ductless) | 100-250W fan | ~37-91 kWh/year (estimate) | Charcoal filters restrict airflow, so the motor works harder per CFM. Add roughly $20-60 a year in replacement filters (estimate), which no fan-wattage table counts. |
Real Cost Examples (18.31c/kWh, EIA July 2026)
Fan energy assumes 1 hour of runtime per day; lighting assumes 3 hours per day. Your cooking habits set the real number.
Typical chimney hood, 150W, 1 hour/day
150 x 1 x 365 = 54,750 Wh = 54.75 kWh/year. 54.75 x $0.1831 = $10.02/year. Under a dollar a month to ventilate a kitchen properly.
Pro-style hood, 300W, 1 hour/day
300 x 1 x 365 = 109.5 kWh/year. 109.5 x $0.1831 = $20.05/year. Double the watts, double the bill; buy CFM you need, not CFM that impresses guests.
ENERGY STAR efficient model, 75W, 1 hour/day
75 x 1 x 365 = 27.375 kWh/year. 27.375 x $0.1831 = $5.01/year. High-efficacy blowers (2.8 CFM/W minimum, many far better) halve the fan bill.
Old halogen hood lights, 2x50W, 3 hours/day
100 x 3 x 365 = 109.5 kWh/year. 109.5 x $0.1831 = $20.05/year. The bulbs can cost more than the fan. Swap to LED and this drops to about $2 a year.
LED hood lights, 10W, 3 hours/day
10 x 3 x 365 = 10.95 kWh/year. 10.95 x $0.1831 = $2.01/year. The cheapest upgrade on this page: LED capsules pay for themselves in months.
Makeup-air heat loss (illustrative example)
An online worked example ran a 1,000 CFM hood for one hour on a cold day and calculated well over 100 kWh of heated air dumped outside, vs the fan's own ~0.3 kWh. The fan electricity is not the expensive part; heating the replacement air is.
How to Calculate Your Range Hood Cost
Step 1: Read the fan nameplate.
Check the rating label inside the hood (usually under the filter). You will see the motor watts, typically 65 to 300W for residential hoods. Note the lighting watts separately; halogen bulbs are often 2x50W, LED about 10W total.
Step 2: Estimate real runtime.
Do not use the 4 hours a day some blogs assume. Track one week honestly: most households run the fan 30 to 90 minutes a day, only while cooking. Use your real number, not a worst case.
Step 3: Do the math.
Watts x hours per day x 365 / 1000 = kWh per year. Example: 150W x 1 hour x 365 / 1000 = 54.75 kWh. Times $0.1831 = $10.02 a year. Add lighting separately: bulb watts x lighting hours x 365 / 1000 x $0.1831.
Step 4: Size-check the CFM.
HVI's rules: gas cooktops need total burner BTU divided by 100 in CFM; electric cooktops against a wall need 100 CFM per linear foot of width (150 for islands). A 40,000 BTU gas range needs 400 CFM. Buying 900 CFM for a 30-inch electric cooktop wastes watts on the motor and heat on the makeup air.
A note on measurement: Many range hoods are hardwired, so a plug-in Kill A Watt meter will not help unless yours plugs into an outlet (some over-range microwaves do). For hardwired hoods, the nameplate rating plate is your best figure, or use a clamp meter on the circuit with an electrician's help. The ENERGY STAR product finder also lists certified hoods with measured CFM per watt, which is the most honest efficiency figure available.
The Hidden Cost: Makeup-Air Heat Loss
Every cubic foot of air your hood throws outside must be replaced by a cubic foot of outdoor air leaking back into your house. Run a 600 CFM hood for an hour and you have exhausted 36,000 cubic feet of conditioned air. On a 10-degree day, your furnace has to heat 36,000 cubic feet of 10-degree air up to room temperature. An enthusiast's worked example of a 1,000 CFM hood ran this math and landed at well over 100 kWh of heating energy for one hour of cooking. The fan itself used about 0.3 kWh.
This is why building codes care. IRC section M1503.6 requires makeup-air provision for hoods over 400 CFM in homes with fuel-burning appliances. A powered makeup-air damper pulls in outside air through a tempered path instead of letting the house suck it in through every crack. Without it, a big hood can backdraft a water heater or furnace, which is a carbon monoxide risk, not just an energy one.
The practical answer is not to stop ventilating. It is to right-size. HVI's formula, total gas BTU divided by 100, exists precisely to stop the 900 CFM habit. A 30-inch electric cooktop against a wall needs about 250 CFM. At 250 CFM, both the fan watts and the makeup-air load stay modest. The 900 CFM island hood in a 200-square-foot kitchen is buying restaurant ventilation for a home kitchen.
If you already have a big hood, run the lowest speed that clears the cooking vapors. CFM and wattage both scale with speed, and so does the makeup-air penalty. Low speed on a right-sized hood is the cheapest way to keep indoor air clean, and it is not close.
How to Actually Cut Range Hood Energy Use
Right-size the CFM before anything else.
This dwarfs every other tip. HVI: gas BTU / 100, or 100 CFM per foot of electric cooktop (150 for islands). A right-sized hood draws less fan power AND dumps less heated air. The 900 CFM hood on a 4-burner electric range is the single most wasteful choice in this category.
Run low speed, not high.
High speed roughly doubles wattage over low, and the makeup-air cost scales with CFM. Start on low; step up only for searing or wok cooking. Most simmering and sauteing clears fine on low.
Swap halogen bulbs for LED.
Old 2x50W halogens at 3 hours a day cost about $20 a year, more than many fans. LED capsules at ~10W total cost about $2. This is the fastest payback in the whole kitchen.
Turn the fan on before the smoke, not after.
Establishing airflow a few minutes before cooking clears vapors on low speed. Chasing a smoke-filled kitchen afterward demands high speed for twice as long.
Clean the grease filter monthly.
A clogged mesh or baffle filter chokes airflow, so the motor works harder and runs longer for the same capture. Ten minutes with degreaser keeps the CFM you paid for.
If you go recirculating, budget the filters.
Charcoal filters run roughly $20-60 a year in replacements (estimate) and restrict airflow, which raises effective fan watts per CFM. Ducted out is more efficient whenever the kitchen layout allows it.
Range Hood Comparisons
Right-sized vs oversized hood: 250 CFM efficient model (~75W): about $5.01/year. 900 CFM pro-style (~300W at high): about $20.05/year. The fan difference is $15 a year, but the makeup-air heating difference on a cold day can be 100 kWh per hour, which is the real bill.
Fan vs halogen lights: 150W fan at 1 hour/day: $10.02/year. 100W of halogen at 3 hours/day: $20.05/year. On many older hoods, the lights are the energy hog, not the blower. LED fixes it for about $2 a year.
ENERGY STAR vs standard blower: Standard (~150W): $10.02/year. Efficient model (~75W): $5.01/year. Savings of about $5 a year (actual savings vary) are modest, but the certified models are also quieter, which is the reason most people notice them.
Ducted vs recirculating: Ducted 150W: $10.02/year fan, no filter cost. Recirculating 200W: about $13.37/year fan plus roughly $20-60 a year in charcoal filters (estimate). Ducted wins on energy and on wallet whenever the house allows it.
Range Hood Energy FAQs
How many watts does a range hood use?
A typical residential range hood fan draws 65 to 300 watts. Under-cabinet models run 65-150W, wall-mount chimney hoods 150-300W, and pro-style high-CFM hoods 300-700W. Recirculating models draw 100-250W.
How much does it cost to run a range hood per year?
At 18.31 cents per kWh and 1 hour a day: a 150W hood costs about $10.02 a year, a 75W efficient model about $5.01, and a 300W pro-style hood about $20.05. The bigger cost is often the heated or cooled air it exhausts (makeup-air loss).
Do range hood lights use a lot of electricity?
Old halogen setups (2x50W) can use more than the fan: about $20 a year at 3 hours a day. LED lights (~10W total) cost about $2 a year. Swapping to LED is the highest-payback upgrade on a range hood.
What CFM range hood do I need?
HVI's rules: for gas, total burner BTU divided by 100 (a 40,000 BTU range needs 400 CFM). For electric or induction against a wall, 100 CFM per linear foot of cooktop width (150 for islands). Oversizing wastes fan energy and makeup-air heat.
Do range hoods need makeup air?
Hoods over 400 CFM generally require makeup-air provision under IRC section M1503.6 in homes with fuel-burning appliances. Without it, a powerful hood can backdraft a furnace or water heater, which is a carbon monoxide risk as well as an energy loss.
Is a ductless range hood less efficient?
The fan draws similar watts (100-250W), but charcoal filters restrict airflow, so it moves less air per watt. Add roughly $20-60 a year in replacement filters (estimate). Ducted-out ventilation is more efficient when the kitchen layout allows it.