How Many kWh Does a Tankless Electric Water Heater Use?

Tankless Electric Water Heater energy cost calculator - see your exact daily, monthly, and yearly electricity cost.

Rate - AUGUST 2026 ⚡ 18000W typical
1Enter Wattage
→
2Set Hours
→
3See Costs
$

US national average. Edit for your local rate.

Tankless Water Heater Preset

Instantaneous draw while a hot tap is open. Zero draw the rest of the day.

Daily Energy Use

9.00

kWh / day

Monthly Cost

$49.03

Yearly Cost

$596.56

Tankless Electric Water Heater - Cost Breakdown

Period kWh Used Cost ($)
Per Hour 18.0000 $3.2688
Per Day 9.00 $1.63
Per Month (30 days) 270.00 $49.03
Per Year (365 days) 3285.00 $596.56
⚡ Real-World Comparison

A tankless water heater running for 30 minutes uses about the same energy as a clothes dryer running for 3 full cycles.

3 Ways to Cut Your Tankless Electric Water Heater Energy Bill

  • 🌱

    Install low-flow fixtures (1.5 GPM showerheads) to reduce the volume of water that needs heating.

  • 💡

    Set the output temperature to 120°F — tankless units heat on demand, so there's no reason to set it higher and mix with cold.

  • ⚡

    Flush the unit with vinegar annually to remove mineral scale that insulates the heat exchanger and reduces efficiency.

Startup Surge Information

Tankless water heaters use high-wattage resistance elements that activate instantly at full power with no surge beyond their rated draw.

How Much Electricity Does a Tankless Water Heater Really Use?

Last Updated: October 2026 | Reviewed by James Vance, Licensed Master Electrician

Here is the short answer I give homeowners: a tankless electric water heater for a family of four uses about 10.4 kWh a day, or about 3,800 kWh a year, which is about $695 a year at 18.31 cents per kWh. One 10-minute shower uses about 3.2 kWh, or about 58 cents. The unit itself draws a huge amount of power, 18,000 to 36,000 watts, but only while a hot tap is open. It uses zero power the rest of the day.

That is the number most websites get wrong. The internet is full of claims that a tankless heater uses 20 to 50 kWh a month. That figure would only heat 4 to 8 gallons of water a day, roughly one short shower. A real family uses about 64 gallons of hot water a day, and heating that water takes about 10.2 kWh of heat energy no matter what kind of heater you own. The physics does not care about the marketing. The tankless saves money by not keeping a tank hot all day, not by heating water with less energy.

In 15 years of electrical work I have wired plenty of tankless units, and the question homeowners should ask first is not the running cost, it is the panel. A 24 kW unit needs a 100-amp dedicated circuit, a 36 kW unit needs 150 amps, and many homes need a 200-amp service upgrade before the first shower. The running cost is honest and predictable. The install cost is where the surprises live.

Tankless Electric Water Heater Sizes: Real Energy Numbers

Flow rates and breaker sizes are from the Rheem EcoSmart spec sheet at a 68-degree rise (40-degree inlet, 108-degree outlet). Energy per shower is the same for every size at the same flow, because the water needs the same heat. The bigger unit heats more water at once, it does not use more energy per gallon. Costs at 18.31 cents per kWh.

Type Running Watts Annual Use Notes
Small whole-house (18 kW, 75A breaker) 18000W About 1.8 GPM at a 68F rise One shower at a time in a warm climate. Needs a 75-amp dedicated circuit. Best for 1-bath homes and apartments.
Mid-size whole-house (24 kW, 100A breaker) 24000W About 2.4 GPM at a 68F rise One shower plus a faucet. Needs a 100-amp dedicated circuit. The most common size for a 2-bath home.
Large whole-house (27 kW, 113A breaker) 27000W About 2.7 GPM at a 68F rise Shower plus a second fixture at once. Needs about 113 amps. Check the panel before buying this size.
Extra-large whole-house (36 kW, 150A breaker) 36000W About 3.6 GPM at a 68F rise Two showers at once. Needs a 150-amp dedicated circuit, and the manufacturer lists a 300-amp service for this model. Panel upgrade is likely.

Real Cost Examples (18.31c/kWh, EIA July 2026)

Cost = watts x hours / 1000 x $0.1831, or from the physics: kWh = gallons x 8.34 x temperature rise / 3,412. The first example is the site calculator default. The rest use the DOE average of 64 gallons of hot water a day for a family, with a 65-degree rise to a 120-degree setpoint.

Site default, 18000W, 30 minutes a day

18000 x 0.5 x 365 / 1000 = 3,285 kWh/year. 3,285 x $0.1831 = $601.48/year or $50.12/month. This is close to a real family, because 30 minutes of hot-water runtime a day is about right.

Family of four, 64 gallons a day, 65F rise

64 x 8.34 x 65 / 3,412 = 10.2 kWh/day of heat into the water. At UEF 0.98 the unit draws about 10.4 kWh/day. 10.4 x 365 = 3,796 kWh/year. 3,796 x $0.1831 = $695.05/year or $57.13/month.

One 10-minute shower, 2 GPM, 65F rise

20 gallons x 8.34 x 65 / 3,412 = 3.18 kWh. 3.18 x $0.1831 = $0.58 per shower. A family of four showering daily spends about $2.33 a day on showers, or about $70 a month.

Low-use home, 41 gallons a day, 65F rise

41 x 8.34 x 65 / 3,412 = 6.51 kWh/day. 6.51 x 365 = 2,378 kWh/year. 2,378 x $0.1831 = $435.34/year or $35.78/month. DOE says homes at 41 gallons a day or less save 24 to 34 percent versus a storage tank.

Dishwasher cycle, about 6 gallons of hot water

6 x 8.34 x 65 / 3,412 = 0.95 kWh. 0.95 x $0.1831 = $0.17 per cycle. A warm laundry load at 15 to 20 gallons uses about 2.4 to 3.2 kWh, or about $0.44 to $0.59.

Tankless vs storage tank, family of four

Tankless draws about 10.4 kWh/day. A storage tank draws about 11.9 kWh/day, because about 1.5 kWh a day is standby loss keeping the tank hot. Saving 1.5 x 365 = 547.50 kWh/year. 547.50 x $0.1831 = $100.25/year saved, and the tankless lasts 20-plus years versus 10 to 15 for a tank.

How to Calculate Your Tankless Water Heater Cost

Step 1: Count your gallons of hot water per day.

DOE uses 64 gallons a day for an average family. A 10-minute shower at 2 GPM is 20 gallons. A dishwasher cycle is about 6 gallons. A warm laundry load is 15 to 20 gallons. Add up your household, or use 64 gallons as the starting point.

Step 2: Work out the heat energy with the physics formula.

kWh = gallons x 8.34 x temperature rise / 3,412. The temperature rise is your setpoint minus your incoming water temperature, usually about 65 degrees to reach 120F. For 64 gallons: 64 x 8.34 x 65 / 3,412 = 10.2 kWh a day of heat into the water.

Step 3: Divide by the UEF to get the electricity drawn.

Electric tankless units run at UEF 0.91 to 0.99, typically about 0.98. So 10.2 / 0.98 = about 10.4 kWh a day from the wall. Multiply by your rate: 10.4 x $0.1831 = $1.90 a day, or about $57.13 a month.

Step 4: Add nothing for standby, because there is none.

A tankless heater has no stored water, so there is no standby loss. That is the whole saving versus a tank, about 1.5 kWh a day for a family, or about $100.25 a year. The idle electronics draw is only a few watts (estimate) and is not worth counting.

A note on measurement: A plug-in meter cannot measure a tankless water heater, because whole-house units run on 240 volts and are hardwired on a dedicated circuit. The honest way to check your number is the physics formula above, or a clamp meter on the feeders installed by an electrician. Never open a panel or clamp a live 240-volt circuit yourself. The gallons-and-rise math is accurate to within a few percent, because the heater has no standby loss to hide.

Kilowatts Are Not Kilowatt-Hours: The One Idea That Explains Tankless Bills

The single biggest confusion about tankless heaters is the difference between kilowatts and kilowatt-hours. Kilowatts are power, how fast the unit draws electricity. Kilowatt-hours are energy, how much it uses in total. A 24 kW tankless heater draws 24,000 watts while it runs, which sounds terrifying, but it only runs while a tap is open. A family that runs hot water for 30 minutes a day uses 24 x 0.5 = 12 kWh a day at most, and the real number is closer to 10.4 kWh because the unit modulates down when the flow is low. The 24 kW number is the sprint speed. The 10.4 kWh number is the distance.

The formula that ties them together is simple: kW = GPM x 500 x temperature rise / 3,412. At a 70-degree rise, every gallon per minute of flow needs about 10.3 kW. A 2 GPM shower at a 70-degree rise needs about 20.6 kW, which is why a 24 kW unit can run one shower comfortably but struggles with two. In cold climates, where the incoming water is 40 degrees and the rise is 80 degrees, the same 2 GPM shower needs about 23.5 kW, and a 24 kW unit is right at its limit. That is why sizing starts with your coldest incoming water temperature, not with the marketing brochure.

This is also why the 20 to 50 kWh a month claim you see on so many websites is wrong. At 18.31 cents, 50 kWh a month is $9.16, which sounds wonderful, but 50 kWh a month only heats about 8 gallons a day, roughly one short shower. A family of four uses about 64 gallons a day, which is about 312 kWh a month, or about $57. The competitors quoting 20 to 50 kWh a month are either quoting a single-person apartment or repeating a number they never checked against the physics. Do the gallons math yourself and you will never be fooled by it.

The practical gotcha is the panel, and it is the part I spend the most time explaining on site. A 24 kW unit needs a 100-amp dedicated circuit, a 27 kW unit needs about 113 amps, and a 36 kW unit needs 150 amps, with the manufacturer listing a 300-amp service for its largest model. Many homes have a 100-amp or 150-amp service for the whole house, so the tankless alone can exceed the service. Before you buy, have an electrician check the service size, the spare breaker spaces, and the wire run. The running cost is about $695 a year for a family. A service upgrade can cost several times that, once.

How to Actually Cut Tankless Water Heater Costs

Set the output to 120F, not higher.

DOE and most manufacturers recommend 120F. Every extra 10 degrees of rise adds about 15 percent more energy per gallon, and you mix the extra heat away with cold water at the tap anyway. A 120F setpoint is safe, comfortable, and cheaper (actual savings vary with inlet temperature).

Install low-flow showerheads, 1.5 GPM or less.

Energy use is proportional to gallons, not to time. A 1.5 GPM showerhead instead of a 2 GPM head cuts the hot water per shower by 25 percent, and the electricity with it. A 10-minute shower drops from about 3.2 kWh to about 2.4 kWh, saving about $0.15 per shower (actual savings vary).

Take shorter showers.

Cutting a 10-minute shower to 7 minutes saves 30 percent of the shower energy, about $0.17 a shower at 2 GPM. Four people doing that every day saves about $250 a year. It is the single biggest lever on a tankless bill, and it costs nothing.

Flush the heat exchanger with vinegar once a year.

Mineral scale insulates the heat exchanger, so the unit has to work harder to deliver the same hot water. An annual vinegar flush takes about an hour and keeps the UEF where the manufacturer rated it. In hard-water areas, do it every 6 months (actual savings vary with water hardness).

Do not oversize the unit.

A 36 kW unit does not use more energy per gallon than an 18 kW unit, but it costs more to buy, needs a bigger panel, and short-cycles on low flows. Size the unit to your real peak flow, usually one or two fixtures at once, not to every tap in the house running at the same time.

Wash laundry in cold water when you can.

A warm laundry load uses about 2.4 to 3.2 kWh of hot water energy, or about $0.44 to $0.59. A cold load uses none of it. Modern detergents work well in cold water, and switching most loads to cold is the easiest saving on this list.

Tankless Water Heater Comparisons

Tankless vs storage tank, family of four: A tankless draws about 10.4 kWh a day. A storage tank draws about 11.9 kWh a day, with about 1.5 kWh a day lost as standby heat. The tankless saves about $100.25 a year, lasts 20-plus years versus 10 to 15 for a tank, and never runs out of hot water.

Low-use vs high-use home: A home using 41 gallons a day draws about 6.51 kWh a day, or about $435.34 a year. A home using 86 gallons a day draws about 13.7 kWh a day, or about $913 a year. DOE says the efficiency advantage over a tank is biggest, 24 to 34 percent, at 41 gallons a day or less.

One shower vs one dishwasher cycle: A 10-minute shower at 2 GPM uses about 3.18 kWh, about $0.58. A dishwasher cycle at about 6 gallons uses about 0.95 kWh, about $0.17. The shower is the biggest single hot-water use in most homes, by a wide margin.

Electric tankless vs gas tankless: Electric tankless units run at UEF 0.91 to 0.99 and have no pilot light and no venting, but they need 100 to 150 amps of panel capacity. Gas tankless units can deliver higher flow rates, and ENERGY STAR certifies gas models at UEF 0.95 or higher. ENERGY STAR publishes no electric-tankless UEF threshold, so do not shop for an ENERGY STAR electric tankless, it does not exist as a category.

Tankless Water Heater Energy FAQs

How many watts does a tankless electric water heater use?

Whole-house electric tankless units are rated 18,000 to 36,000 watts: 18 kW for a small home, 24 kW for a typical 2-bath home, 27 kW for a large home, and 36 kW for two showers at once. That is the instantaneous draw while a tap is open. The unit draws nothing when no hot water is running.

How much does a tankless water heater cost to run per month?

About $57 a month for a family of four at 18.31 cents per kWh, based on 64 gallons of hot water a day. A low-use home at 41 gallons a day costs about $36 a month, and a high-use home at 86 gallons a day costs about $76 a month. The bill follows your gallons, not the kW rating.

Does a tankless water heater use a lot of electricity?

It draws a lot of power, 18 to 36 kW, but only for minutes at a time, and it uses about 10.4 kWh a day for a family, which is about 13 percent less than a storage tank at 11.9 kWh a day. The big number is the panel requirement, not the monthly bill. A 24 kW unit needs a 100-amp dedicated circuit.

How much electricity does one shower use with a tankless heater?

About 3.18 kWh, or about $0.58 at 18.31 cents per kWh, for a 10-minute shower at 2 GPM with a 65-degree temperature rise. A low-flow 1.5 GPM showerhead cuts that to about 2.4 kWh, or about $0.44.

Is a tankless water heater cheaper than a storage tank?

Yes, by about $100 a year for a family of four, because the tankless has no standby loss. DOE says demand heaters are 24 to 34 percent more efficient than storage tanks for homes using 41 gallons a day or less, and 8 to 14 percent more efficient at about 86 gallons a day. The tankless also lasts 20-plus years versus 10 to 15 for a tank.

What size breaker does a tankless water heater need?

An 18 kW unit needs a 75-amp breaker, a 24 kW unit needs 100 amps, a 27 kW unit needs about 113 amps, and a 36 kW unit needs 150 amps. Many homes need a service upgrade to 200 amps, and the largest models list a 300-amp service. Have a licensed electrician check your panel before buying.